Dynalco Catalyst Monitor Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Panel sterowania Dynalco Catalyst Monitor. Dynalco Catalyst Monitor User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 26
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
5450 NW 33rd Ave, Suite 104
Fort Lauderdale, FL 33309
3211 Fruitland Ave
Los Angeles, CA 90058
Catalyst Monitor
6-Channel Monitor
Version 2
Installation and Operation Manual
Rev. I
P/N145F-12964
PCO - 00007462
(c) Copyright 2014, Dynalco Controls
All Rights Reserved
Published: November 7, 2014
Przeglądanie stron 0
1 2 3 4 5 6 ... 25 26

Podsumowanie treści

Strona 1 - Catalyst Monitor

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL 33309 3211 Fruitland Ave Los Angeles, CA 90058 Catalyst Monitor 6-Channel Monitor Version 2 I

Strona 2

9Programming Instructions Important: The Catalyst Monitor must first be programmed prior to operation. When initially powering up the unit, the dis

Strona 3

10A description of each menu item follows: “Run Signal” There are (3) run types available. The definitions are as follows: None: No run indicati

Strona 4

11”Calibration” Select the channel number to configure by pressing the up / down arrows and pressing the right arrow to select and continue. Th

Strona 5

12“Communication” This allows configuration for downloading data and Modbus communications. ”Data Logging” The setup for EPA required logging of

Strona 6

13Select “A Value” on the next screen and press the arrow. On the following screen, select an RPM value that will indicate engine runni

Strona 7

14Pressing the escape key two times will escape to the normal monitoring mode. “System” “Display defaults” allows the selection of either sing

Strona 8

15Alarm Outputs The Catalyst Monitor will alarm when channel values or differential values are above or below limits as specified. Alarms can be

Strona 9

16Downloading logged values to PC using LogReader software The hardware connection from the Catalyst Monitor to a PC is via a USB cable a

Strona 10

17There are (3) reports generated by the LogReader software: The report named “CatalystDataLog” is a spreadsheet of logged values as configured in t

Strona 11

18The 2nd report named “CatalystDataLogEPAInstant” contains the instantaneous catalyst inlet temperatures taken at 15 minute intervals. Note tha

Strona 12

1IMPORTANT - PLEASE READ BEFORE PROCEEDING! This manual applies to all Version2 Catalyst Monitors. The Dynalco Catalyst Monitor is designed for rel

Strona 13

19Modbus Communication The unit also provides access to the internal registered values using the Modbus Protocol. The diagram below sh

Strona 14

20Modbus Address Registers: The Modbus address registers are defined in the tables below. Input Register Table (table 1) Modicon Address Modbus Of

Strona 15

21300017 16 Channel 5 High Alarm Limit -32768 32767 16 bit signed integer 300018 17 Channel 6 High Alarm Limit -32768 32767 16 bit signed integer 330

Strona 16

22301046-301049 1045-1048 Log Buffer Entry #12 Custom (See table 4) 301050-301053 1049-1052 Log Buffer Entry #13 Custom (See table 4) 301054-

Strona 17

23302006-302007 2005-2006 Channel 3 Float Value -9999.0 99999.0 32 bit Float(IEEE 754) 302008-302009 2007-2008 Channel 4 Float Value -9999.0 99999.0

Strona 18

24302048-302049 2047-2048 Channel 6 High Low Limit -9999.0 99999.0 32 bit Float(IEEE 754) 302050-302051 2049-2050 Channel 1 and 2 Differential Low Al

Strona 20

2System Overview The Dynalco Catalyst Monitor is designed to address the EPA mandate regarding continuous monitoring of catalyst inlet temperatu

Strona 21 - Modbus Address Registers:

3Flash Memory: The onboard flash memory is sufficient to hold up to 500,000 data values with date / time stamp. When the Catalyst

Strona 22

4User Interface The Catalyst Monitor is configured via the keypad on the front panel which includes a graphical backlit LCD display

Strona 23

5The Catalyst Monitor has integral mounting clips for securing into the panel. The following drawings illustrate the mounting procedure.

Strona 24

6Terminal Connections All connections are made via the removable connectors on the back of the unit. PIN Description PIN Description 1 GND (P

Strona 25

7Outline Dimensions

Strona 26

8Programming Overview All programming is accomplished through the front keypad. Below is a brief description of each key. Press to enter or exit t